Electrical
Operating
Voltage: 24VDC +/−10% (Power
Adaptor Module Included).
Power
Consumption: <2AMPS (Triple Track
Reading & Writing at High Coercivity).
MTBF: 160,000 Power On Hours.
Encoding/Decoding
Density: 75 or 210 BPI, for each track.
Media
Coercivity: 250 to 4200 oersted
Communication: RS-232, USB-CDC
Environmental
Operating
Temperature: 32° F to 122° F (0°
C to 50° C). Maximum 95% non-condensing
Storage
Temperature: 14° F to 140° F
(-10° C to 60° C), non-condensing.
Reliability
Read
Head Life: 1,000,000 passes minimum.*
Write
Head: 1,000,000 passes minimum.*
Low
Amplitude: Read >30%@210 BPI, >40%@75
BPI.
Write
Performance: Meets or exceeds ISO 7811
requirement for new cards.
Warranty: One year, parts and labor.
Agency: FCC Class A, CE Class A, and UL Listed.
Mechanical
Card
Formats: ISO/ANSI, AAMVA, and “USER”
(Custom).
Available
Configurations: Tracks 1 and 2 or Tracks
1, 2, and 3.
Swipe
Speed (Reading): 5 to 55 inches per
second.
Swipe
Speed (Writing): 5 to 35 inches per
second.
Media
Thickness: .007 to .045 inches.
Weight: 3 lb (1.36 kg).
Dimensions
(HxWxL): 2.6 inches (67 mm) x 2.5 inches
(64 mm) x 8.0 inches (204 mm) (includes feet)
Color: Beige.
Housing: Die cast zinc (ZAMAK).
Workshop
Software Application Features
Write Writes data to a card in the Card Type
format
Read Reads card data and displays the data in
Track boxes
Compare Compares multiple cards to a single
reference card
Erase Erases the selected tracks of data on a
card
Sequential
Write Writes both fixed and/or
sequential data to a card
Write
from File Writes to each card the next
record from a file
Read
to File Reads a card and enters the data
as a record into a file
Database
Write Writes cards from a database CSV
file and Setup file
Card
Type Provides card format selection
based on Setup and Standards
– ISO Selects 7811 ISO Standard card format
– AAMVA Selects AAMVA standard, based on ISO
Standards
– USER Selects the card format from settings
in Setup USER tab
– RAW Reads and writes data and displays in a
Hexadecimal format
Setup Provides selections and settings of
formats and track parameters
– Leading
Zero Sets number of leading zeros
before the Start Sentinel
– BPI
Setting Selects individual track data
density (75 or 210 bits/inch)
– Set
Coercivity Sets the writing coercivity
to High or Low (all tracks)
-–
Start Sentinel Selects the Start
Sentinel character for the individual tracks
– End
Sentinel Selects the End Sentinel
character for the individual tracks
– Bits/Character Selects the number of bits per
character for individual tracks
– Parity Selects character parity bit logic for
individual tracks
– Default Resets the parameters and settings to
the standard norms
*
All reliability numbers are based on operation in a benign
environment.
Back to